TDS Series 100 MHz Digital Oscilloscope

TDS Series 100 MHz Digital Oscilloscope

Touchscreen Digital Oscilloscope with 70MHz / 100MHz / 200MHz Bandwidth, 1GS/s / 2GS/s sample rate, 7.6M record length and 50,000 wfms/s waveform refresh rate

Send InquiryChat Now

Product Details

TDS Series 100 MHz Digital Oscilloscope


- 70MHz-200MHz Bandwidth, Max 2GS/s Sample rate

- 7.6M record length

- 50,000 wfms/s waveform capture rate

- waveform zooming (horizontal / vertical), and saving

- FFT points (length, and resolution variable)

- multi-window extension

- 8 inches 800 x 600 pixels high def LCD

- multi- communication interface : USB, VGA, LAN

- LabVIEW supported

- 4 Channel output


Model No.ChannelBandwidthSample RateRecord Length
TDS7074470MHz1GS/s7.6M
TDS71044100MHz1GS/s7.6M
TDS81044100MHz2GS/s7.6M
TDS82044200MHz2GS/s7.6M


Powerful waveform capture rate

Up to 50,000 wfms/s waveform capture rate, restoring random / low-probability event in fine details.

 


 


FAQ


Why is the measured amplitude less than the real value?

Try a small test. Use your 100 MHz oscilloscope to measure a 100MHz, 3.3V amplitude waveform. The measured amplitude isn’t accurate. This issue refers to the bandwidth of oscilloscope.

 

What is bandwidth?

Bandwidth is an essential parameter for an oscilloscope, but what is bandwidth? Bandwidth refers to the analogue bandwidth of the analogue front end of the oscilloscope, and directly determines the oscilloscope’s signal measurement capabilities. Specifically, the oscilloscope bandwidth is the highest frequency when the amplitude of the sine wave measured by the oscilloscope is not lower than the 3dB amplitude of the true sine wave signal (i.e. 70.7% of the true signal amplitude), also known as -3dB cut off frequency point. As the signal frequency increases, the oscilloscope's ability to accurately display the signal level will reduce.

 

When the measured sine wave frequency is equal to the bandwidth of the oscilloscope (oscilloscope amplifier is for the Gaussian response), we can see that the measurement error is about 30%. If the measurement error is required to be 3%, the frequency of the measured signal should be much lower than the oscilloscope bandwidth. For example, using a 100MHz oscilloscope to measure a 100MHz, 1Vpp, sine wave signal, the measurements will be 100MHz, 0.707Vpp, sine wave waveform. This is only the case for a sine wave since most waveforms are much more complex than a sine wave they will contain higher frequencies. So in order to achieve a certain measurement accuracy, we use the oscilloscopes common law that is commonly referred to as 5 times the standard:

The required bandwidth of the oscilloscope = the highest frequency of the measured signal * 5

 

2. Select the bandwidth correctly

 

Complex signals in a waveform are formed by a variety of different harmonic sine wave signals, and the bandwidth of these harmonics may be very wide. When the bandwidth is not high enough, the harmonic components will not be effectively amplified (blocked or attenuated), which may cause amplitude distortion, edge loss, loss of detail data, etc. The signal characteristics such as bells and tones, etc. will have no reference value.

So, for different frequency signal measurements, the correct bandwidth is very important. When measuring high frequency signals, such as measuring a 27MHz crystal, you should use the full bandwidth measurement.

If the bandwidth limit is enabled, that is, the bandwidth limit is set to 20MHz, the crystal waveform will be distorted and the measurement will be of no value. When measuring low-frequency signals, you should set the bandwidth limit to enable the high-frequency signal interference filter, this is so the signal shows more clearly.

 

3. Bandwidth and rise time

 

With regards to bandwidth, the rise time cannot be ignored. The rise time is usually defined as the time at which the signal amplitude changes from 10% of the maximum steady value to 90%.

 

The bandwidth of the oscilloscope can directly show the minimum rise time of the signal. The rise time of the oscilloscope system can be evaluated from the specified bandwidth. You can use formulate: RT (rising time) = 0.35 / BW (bandwidth) (oscilloscope below 1GHz) to calculate.

 

Where 0.35 is the scale factor between the oscilloscope bandwidth and the rise time (10% -90% rise time in the first order Gaussian model). According to the above formula, if the bandwidth of the oscilloscope is 200MHz, can calculate RT = 1.75ns, that is, the minimum observable rise time.



 


Model TDS7074TDS7104 TDS8104 TDS8204
Bandwidth70MHz100MHz200MHz
Channel4
Sample Rate1GS/s2GS/s
Waveform Capture Rate50,000 wfms/s
Display8" touch screen color LCD
Record Length7.6M
Horizontal Scale (s/div)2ns/div - 100s/div, step by 1 - 2 - 5
Vertical Resolution (A/D)8 bits resolution (4 channels simultaneously)
Vertical Sensitivity2mV/div - 10V/div (at input)
Trigger TypeEdge, Pulse, Video, Slope
Trigger ModeAuto, Normal, Single
Waveform Math+, -, ×, ÷, FFT
Communication PortUSB host, USB device, VGA, LAN、AUX
Dimension (W×H×D)380 × 180 × 115 (mm)
Weight (without package)1.5 kg



 

SUPPORT

▶ USB driver for all series OWON DSO and AWG       xz.gif

▶ PC software for TDS Series DSO       xz.gif

▶ TDS Series DSO user manual       xz.gif


ACCESSORIES   The accessories subject to final delivery.

2013827153299062.jpg

Power Cord

2013827154174210.jpg

CD Rom

2013827155525321.jpg

Quick Guide

2013827156225645.jpg

USB Cable

201382715794157.jpg

Probe

2013827157371853.jpg

Probe Adjust

20138271652585315.jpg

Soft Bag
(optional)


 

 

 

 

 

Inquiry